Phone:(+86) 18625862121
Email:order@zzsteels.com
newsbanner
You are here: Home » News » Company News » Lap Joint Stub End Weight Calculation and Chart

Lap Joint Stub End Weight Calculation and Chart

Views: 197     Author: Site Editor     Publish Time: 2023-02-02      Origin: Site

Why Calculate Weight of Lap Joint Stub End?

The calculator weight is used to choose the package and transportation method, beause Lap joint stub end is usually in small demands. It is generally a section of the lap joint flange.The stainless steel stub end is matched with the galvanized carbon steel lap joint flange for saving cost. There are 3 types.


l Type A is employed for standard joint flange

l Type B is employed for standard slip on flanges as lap flanges.

l Type C will be used for standard lap joint flange, and put on flange.


How to Calculate Weight of Lap Joint Stub End?

Option 1

The weight can be found from the below chart. It is common and widely used thickness schedule in the pipeline system.


Stainless Steel Lap Joint Stub End Weight Chart in kg

DN

NPS

SCH10S

SCH40S

SCH80S

SHORT PATTERN

LONG PATTERN

SHORT PATTERN

LONG PATTERN

SHORT PATTERN

LONG PATTERN

15

1/2

0.07

0.09

0.09

0.12

0.12

0.16

20

3/4

0.09

0.12

0.12

0.16

0.15

0.21

25

1

0.15

0.25

0.18

0.32

0.24

0.43

32

11/4

0.19

0.34

0.25

0.43

0.33

0.57

40

11/2

0.22

0.39

0.31

0.52

0.43

0.75

50

2

0.35

0.71

0.52

1.02

0.73

1.49

65

21/2

0.46

0.95

0.81

1.60

1.10

2.22

80

3

0.62

1.22

1.10

2.11

1.5

2.98

90

31/2

0.70

1.36

1.52

2.55

2.09

3.65

100

4

0.94

1.59

1.80

3.05

2.58

4.44

125

5

1.30

2.80

2.25

5.42

3.60

7.86

150

6

1.75

3.30

3.59

7.02

5.76

11.3

200

8

2.9

4.95

5.98

10.6

9.18

16.2

250

10

4.79

8.50

10.2

18.4

13.7

24.9

300

12

7.2

10.9

14.9

22.8

19.5

30.2

350

14

7.95

15.0

15.8

28.7

2.16

38.6

400

16

9.50

17.3

18.9

33.1

25.2

44.5

450

18

11.1

19.8

22.0

38.0

29.3

51.1

500

20

14.1

25.9

24.3

42.3

32.6

56.8

550

22

16.5

28.2

-

-

-

-

600

24

19.8

35.0

29.6

51.2

39.7

68.8








Option 2

Stub End Callucation Formula

You can also get the weight by calculation formula / calculator.

W=0.0251352 x 0.001 x [t x ({G²-OD²}/4+(F x t x (OD-t)]



Where:

W = Weight of lap joint stub end in kg.

OD = Outside diameter of barrel (mm) same as pipe

T= Wall Thickness(mm) same as pipe

F = Length of barrel (mm) from below chart

G = Diameter of Lap (mm) from below chart



DN

NPS

OD

F

T

G

MAX

MIN

LONG PATTERN

SHORT PATTERN

SCH10S

SCH40S

SCH80S

15

1/2

22.8

20.5

76

51

2.11

2.77

3.73

35

20

3/4

28.1

25.9

76

51

2.11

2.87

3.91

43

25

1

35

32.6

102

51

2.77

3.38

4.55

51

32

11/4

43.6

41.1

102

51

2.77

3.56

4.85

64

40

11/2

49.9

47.5

102

51

2.77

3.68

5.08

73

50

2

62.4

59.5

152

64

3.05

3.91

5.54

92

65

21/2

75.3

72.2

152

64

3.05

5.16

7.01

105

80

3

91.3

88.1

152

64

3.05

5.49

7.62

127

90

31/2

104

100.8

152

76

3.05

5.74

8.08

140

100

4

116.7

113.5

152

76

3.05

6.02

8.56

157

125

5

144.3

140.5

203

76

3.40

6.55

9.53

186

150

6

171.3

167.5

203

89

3.40

7.11

10.97

216

200

8

222.1

218.3

203

102

3.76

8.18

12.7

270

250

10

277.2

272.3

254

127

4.19

9.27

15.09

324

300

12

328.0

323.1

254

152

4.57

9.52

17.48

381

350

14

359.9

354.8

305

152

4.78



413

400

16

411

405.6

305

152

4.78



470

450

18

162

456.0

305

152

4.78



533

500

20

514

507.0

305

152

5.54



584

550

22

565

558.0

305

152

5.54



641

600

24

616

609.0

305

152

6.35



692


CONTACT US
Tel: (+86) 372-2155516
Mobile: (+86) 18625862121
Email:order@zzsteels.com
Contact: Jerry Zhao
Address: No 888 Xigangshen Road Jiading Shanghai

QUICK NAVIGATION

WECHAT QR CODE
COPYRIGHT© 2018 SHANGHAI ZHUCHENG PIPE FITTINGS MANUFACTURING CO LTD. ALL RIGHTS RESERVED
TECHNICAL SUPPORT : COVERWEB